Freewaregruppe Monitoring/Nagios-Plugins
check_intel_rst is a Windows plugin for Nagios which checks the status of Intel’s Rapid Storage Technology (RST) RAIDs.
check_intel_rst is a Windows plugin for Nagios which checks the status of Intel’s Rapid Storage Technology (RST) RAIDs.
The plugin determines the status of Raids, Raid-Controllers and of individual discs (S.M.A.R.T), while all stripe sets are supported.
Installation of Intel RST Commandline Tool (rstcli.exe).
Usually you open the script with the path to CLI:
C:\> check_intel_rst.exe path=”c:\Program Files (x86)\Intel\Intel(R) Rapid Storage Technology enterprise”
RST RAID OK: Intel(R) C600+/C220+ series chipset sSATA AHCI Controller – Intel(R) C600+/C220+ series chipset SATA RAID Controller – Volume: RAID1, [RAID1], 106 GB, (Normal) – Disk: 0-1-0-0, 111 GB, (Normal) – Disk: 0-0-0-0, 111 GB, (Normal)
For debugging purposes, it may also be called with a more detailed output option (this mode is not suitable for continuous operation, but for testing purposes only). Afterwards it will output the detailed status of the individual components:
C: > check_intel_rst.exe path=”c:\Program Files (x86)\Intel\Intel(R) Rapid Storage Technology enterprise”
RST RAID CRITICAL: Intel(R) C600+/C220+ series chipset sSATA AHCI Controller – Intel(R) C600+/C220+ series chipset SATA RAID Controller – Volume: RAID1, [RAID1], 106 GB, (Degraded) – Disk: 0-1-0-0, 0 GB, (Missing) – Model: – SNR: 2NJNXAG900363P – Disk: 0-0-0-0, 111 GB, (Normal)
For information on the plugin and its usage you can call it with the help command:
C:\> check_intel_rst.exe path=”c:\Program Files (x86)\Intel\Intel(R) Rapid Storage Technology enterprise”
RST RAID CRITICAL: Intel(R) C600+/C220+ series chipset sSATA AHCI Controller – Intel(R) C600+/C220+ series chipset SATA RAID Controller – Volume: RAID1, [RAID1], 106 GB, (Rebuilding) – Disk: 0-1-0-0, 111 GB, (Normal) – Disk: 0-0-0-0, 111 GB, (Normal)
check_intel_rst - Revision: 1.0 Copyright (C) 2016 LuftEngineering GmbH Report Bugs to:info@luft-it.de check_intel_rst plugin for Nagios. Monitors integrity of a Intel RAID System with rstcli.exe Usage: path - Full path to rstcli.exe (required) args - Arguments for rstcli.exe (default = '-I -c') timeout - Seconds before the plugin times out (default = 15) version - Plugin version help - Show this text debug - Print details. NOT for use with Nagios
Preferably the plugin is copied into the script directory where you will store your checks under Windows
When using NSClient ++ an entry in NSC.INI similar to this is generated and pointed to tw_cli:
... [/settings/NRPE/server] allow arguments=true [/settings/external scripts/server] allow arguments=true [/settings/external scripts/scripts] check_intel_rst=c:\nsclient++\scripts\check_intel_rst.exe path=“ C:\Program Files (x86)\Intel\Intel(R) Rapid Storage Technology enterprise “ ...
Check Intel-Controller with 2 Harddiscs in Raid-1, things are fine…:
C:> check_intel_rst.exe path=“C:\Program Files (x86)\Intel\Intel(R) Rapid Storage Technology enterprise “
RAID OK: Volume: Disk_Vol1 [RAID 1] – Normal Disk: Hitachi HDS72404DA - Disk: OK; Hitachi HDS72404DA – Disk: OK
Check Intel-Controller with 2 Harddiscs in Raid-1 Verbund, one harddisc is obviously failed due to no power:
C:> check_intel_rst.exe path=“C:\Program Files (x86)\Intel\Intel(R) Rapid Storage Technology enterprise “
RAID WARNING: Volume: Disk_Vol1 [RAID 1] – Degraded Disk: Disk0 - Disk: OK; Disk1 – BusID: 1 – Model: Hitachi HDS72404DA – SNR: HDR35549987AD – Status: DISK_POWERED_OFF
2016-13-07
1.2 – Bug fixed at physical drive detection
2016-07-04
1.1 – Bug fixed with SSD / HDD detection
2016-11-02
1.0 – First public version
Check_intel_rst is licensed under the GNU General Public License.
Joachim Luft will answer your questions to this plugin and is happy about your donation.